Type

NTDH

Short description

NTDH utilizing ground for house heating

Location

"Max-Ernst-Straße" area in Schifferstadt

Country

Germany

End users

38 houses

Heat source

Ground

Description

Brine circulates through network and goes to central station from which it goes to HP (at consumer substations) for SH and DHW

Cooling

Yes

Heat source-network connection

HEX? (Missing info)

Booster HP or no for SH

HP

Booster HP, IHEU or DHSU for DHW

HP

TES

Vertical ground HEX (28 boreholes 100 m depth)

Centralized/ Decentralized TES

Centralized

Category

1.1.1.1.1.*

Tsource [°C]

12

Installed capacity [MW]

0.23

Reference 1

https://www.energieagentur.rlp.de/service-info/die-energieagentur-informiert/aktuelle-meldungen/aktuelles-detail/kalte-nahwaerme-konzept-der-energieagentur-ueberzeugt-schifferstadt/

Reference 2

https://doi.org/10.1016/j.rser.2018.12.059