Type

NTDH

Short description

NTDH utilizing ground water for residential heating

Location

Brig-Glis

Country

Switzerland

End users

5 buildings (50 apartments)

Heat source

Ground water

Description

Ground (ground water) heats network which is connected to 5 HPs at consumer substations for SH and DHW

Cooling

Yes

Heat source-network connection

Central HP utilizes ground water?/Water through HEX exchanges heat with network?/Ground water runs through the network? (Missing info)

Booster HP or no for SH

HP

Booster HP, IHEU or DHSU for DHW

HP

Category

1.4.1.1.1.*

Tsupply,min [°C] (network)

8

Tsupply,max [°C] (network)

18

SCOP=(reference annual heating demand)/(seasonal electricity consumption for heating) [-]

4

Heating demand [MWh/year]

410

Reference 1

https://www.brig-glis.ch/online-dienste/stadtinfo/files27/info37energie_brig_screen.pdf

Reference 2

https://www.enalpin.com/newsletter/files36/newsletter-nr.1-2016.pdf

Reference 3

https://doi.org/10.1016/j.rser.2018.12.059

Reference 4

https://www.brig-glis.ch/energiestadt/files12/flyer_masterplanenergie18_online.pdf

Number 27