Type

LTDH

Short description

LTDH utilizing geothermal heat for residential heating

Location

Kırşehir

Country

Turkey

End users

1,800 standard dwellings in high-rise multi-family buildings (no need for renovation because heating system in buildings was oversized)

Heat source

Geothermal

Description

Geothermal power plant that produces heat sold in DH network; SH stops when there is need for DHW; Geothermal network is connected via HEX to distribution network; There is indication that there is direct connection between distribution network and consumer; Temperature of geothermal source is in range 56 to 57°C (return temperature 38°C); 2 oil boilers raise supply temperature of distribution network to 61°C during peak load

Cooling

Missing info

Heat source-network connection

HEX

Booster HP or no for SH

No

Booster HP, IHEU or DHSU for DHW

IHEU

Category

1.13.2.1.1.

Costs/Price [€] (Investment; Operation; Cost for the consumer)

Investment: 1.8 mil €; Variable heat price: 59 ct/kWh

Tsource [°C]

57

∆Tsource [°C]

19

Tsupply,max [°C] (network)

54

Tsupply,max [°C] (at consumer substation)

53

Treturn [°C] (network)

41 (network); 40 (consumer substation)

Installed capacity [MW]

16.74

Reference 1

https://www.iea-dhc.org/fileadmin/documents/Annex_X/IEA_Annex_X_Final_Report_2014_-_Toward_4th_Generation_District_Heating.pdf

Number 52