Type

LTDH

Short description

LTDH utilizing pellet boiler for heating of two buildings

Location

Beļava

Country

Latvia

End users

2 insulated buildings

Heat source

Biomass

Description

Central heating boiler (biomass) (first outline is for insulated houses 65°/35°C and second one for other buildings at 80°C/60°C)

Cooling

Missing info

Heat source-network connection

HEX? (Missing info)

Booster HP or no for SH

No

Booster HP, IHEU or DHSU for DHW

IHEU? (Missing info)

Category

1.12.1.1.1.

Tsupply,min [°C] (network)

65

Tsupply,min [°C] (at consumer substation)

55

Treturn [°C] (network)

25 Consumer); 35 (network)

Installed capacity [MW]

0.199

Reference 1

http://www.lowtemp.eu/examples/first-season-with-low-temperature-district-heating-system-pilot-project-in-belava/

Number 74