Type

LTDH

Short description

LTDH utilizing excess heat for town heating

Location

Middelfart

Country

Denmark

End users

City of Middelfart, 5000 consumers

Heat source

Excess heat

Description

Excess heat from industry, reserve capacity that utilizes natural gas or fuel oil

Cooling

Missing info

Heat source-network connection

HEX? (Missing info)

Booster HP or no for SH

No

Booster HP, IHEU or DHSU for DHW

IHEU? (Missing info)

Category

2.1.2.1.1.*

Tsupply,min [°C] (network)

65

Tsupply,max [°C] (network)

67

Treturn [°C] (network)

40

Produced heating energy [MWh/year]

122086 (94491 from excess heat and the rest from gas boilers)

Heating demand [MWh/year]

103462.712 (calculated from data)

Network length [km] (if not specified-pipes, trench specified)

148

Heat loss [%]

18

LHD (linear heat density)=(total heat demand)/(length of network) [kWh/m/year]

699.072 (calculated from data)

Reference 1

https://backend.orbit.dtu.dk/ws/portalfiles/portal/142226895/Untitled.pdf

Reference 2

https://www.upgrade-dh.eu/hr/middelfart-danska/

Number 82